RS PRO RS-218 Handheld Digital Multimeter, True RMS, 200mA ac Max, 200mA dc Max, 600V ac Max
- RS Stock No.:
- 146-9086
- Distrelec Article No.:
- 304-03-989
- Brand:
- RS PRO
Subtotal (1 unit)*
$140.42
(exc. GST)
$161.48
(inc. GST)
Units | Per unit |
|---|---|
| 1 + | $140.42 |
*price indicative
- RS Stock No.:
- 146-9086
- Distrelec Article No.:
- 304-03-989
- Brand:
- RS PRO
Select all | Attribute | Value |
|---|---|---|
| Brand | RS PRO | |
| Multimeter Type | Handheld | |
| Display Type | Digital | |
| Model Number p | RS-218 | |
| Functions Measured | AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Resistance | |
| Absolute Maximum AC Voltage Measurement | 600V ac | |
| Absolute Maximum DC Current Measurement | 200mA dc | |
| Absolute Maximum AC Current Measurement | 200mA ac | |
| Absolute Maximum Resistance Measurement | 40MΩ | |
| Absolute Maximum DC Voltage Measurement | 600V dc | |
| True RMS | Yes | |
| Absolute Maximum Capacitance Measurement | 100µF | |
| Maximum Frequency | 10kHz | |
| AC Current Measurement Resolution | 0.1µA ac | |
| DC Current Measurement Resolution | 0.1µA dc | |
| AC Voltage Measurement Resolution | 1mV ac | |
| Resistance Measurement Resolution | 100mΩ | |
| DC Voltage Measurement Resolution | 0.1mV dc | |
| Capacitance Measurement Resolution | 10pF | |
| Safety Category Level | CAT IV | |
| Best Resistance Measurement Accuracy | ±0.8 % | |
| Best DC Current Accuracy | ±2 % | |
| Height | 116mm | |
| Minimum Operating Temperature | 0°C | |
| Weight | 145g | |
| Best AC Current Accuracy | ±2.5 % | |
| Width | 36mm | |
| Safety Category Voltage | 600V | |
| Maximum Operating Temperature | +40°C | |
| Best AC Voltage Accuracy | ±1 % | |
| Best Capacitance Measurement Accuracy | ±3 % | |
| Dimensions | 59 x 36 x 116mm | |
| Best DC Voltage Accuracy | ±0.5 % | |
| Battery Type | AAA | |
| Length | 59mm | |
| Select all | ||
|---|---|---|
Brand RS PRO | ||
Multimeter Type Handheld | ||
Display Type Digital | ||
Model Number p RS-218 | ||
Functions Measured AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Resistance | ||
Absolute Maximum AC Voltage Measurement 600V ac | ||
Absolute Maximum DC Current Measurement 200mA dc | ||
Absolute Maximum AC Current Measurement 200mA ac | ||
Absolute Maximum Resistance Measurement 40MΩ | ||
Absolute Maximum DC Voltage Measurement 600V dc | ||
True RMS Yes | ||
Absolute Maximum Capacitance Measurement 100µF | ||
Maximum Frequency 10kHz | ||
AC Current Measurement Resolution 0.1µA ac | ||
DC Current Measurement Resolution 0.1µA dc | ||
AC Voltage Measurement Resolution 1mV ac | ||
Resistance Measurement Resolution 100mΩ | ||
DC Voltage Measurement Resolution 0.1mV dc | ||
Capacitance Measurement Resolution 10pF | ||
Safety Category Level CAT IV | ||
Best Resistance Measurement Accuracy ±0.8 % | ||
Best DC Current Accuracy ±2 % | ||
Height 116mm | ||
Minimum Operating Temperature 0°C | ||
Weight 145g | ||
Best AC Current Accuracy ±2.5 % | ||
Width 36mm | ||
Safety Category Voltage 600V | ||
Maximum Operating Temperature +40°C | ||
Best AC Voltage Accuracy ±1 % | ||
Best Capacitance Measurement Accuracy ±3 % | ||
Dimensions 59 x 36 x 116mm | ||
Best DC Voltage Accuracy ±0.5 % | ||
Battery Type AAA | ||
Length 59mm | ||
- COO (Country of Origin):
- CN
RS PRO Pocket Handheld Multimeter with NCV Tester
Features and benefits
• MODE button
• Rotary function
• Hz/% Duty Cycle switch
• Large high contrast 4000 counts LCD display with backlight feature
• Safety category CAT IV, 600V
• Variety of functions including frequency, resistance, capacitance, diode test, continuity
• A range of functions measured including AC Current, AC Voltage, Capacitance, DC Current, DC Voltage, Resistance
• Compact design, ideal for working on the go
• Auto power off to preserve battery life
• Flashlight feature, ideal for working in dark environments
• 200mA fused protection
• Test leads included
• Double molded enclosure offering excellent protection
Applications
Compact design
Non-Contact Voltage Detector and Indicator
WARNING: Risk of Electrocution. Before use, always test the Voltage Detector on a known live circuit to verify proper operation.
1. The non-contact voltage detector operates when the meter is set to any measuring function. The detector does not operate when Auto Power Off turns the meter off or when the rotary function switch is set to the off position.
2. Hold the detector close to the AC voltage being tested.
3. If AC voltage within the specified range is present, the indicator light will illuminate.
NOTE: Insulation type and thickness, and distance from the voltage source and other factors may effect operation. Use other methods to verify live voltage if there is any uncertainty.
NOTE: The detector is designed with high sensitivity. Static electricity or other sources of energy may randomly trip the sensor. This is normal operation.
NOTE: The detector only activates the indicator light when AC voltage is present. It does not indicate the voltage level on the LCD display.
FAQs
Does this include a continuity check?
Does it feature an audible signal?
Does this come with test leads?
Related links
- Amprobe 5XPA Handheld Digital Multimeter 200mA dc Max, 600V ac Max
- RS PRO IDM20 Handheld Digital Multimeter 200mA dc Max, 600V ac Max
- Chauvin Arnoux CA 703 Handheld Digital Multimeter 200mA dc Max, 600V ac Max
- Kyoritsu Handheld Digital Multimeter 10A ac Max 600V ac Max
- FLIR DM66 Handheld Digital Multimeter 10A ac Max 600V ac Max
- Keysight Technologies U1232A Handheld Digital Multimeter 10A ac Max 600V ac Max
- Keysight Technologies U1233A Handheld Digital Multimeter 10A ac Max 600V ac Max
- Fluke 117 Handheld Digital Multimeter 10A ac Max 600V ac Max