Fluke 3000 FC 3000 FC Digital Digital Multimeter True RMS, 400 mA ac, 400 mA dc, 1 kV ac
- RS Stock No.:
- 811-1316
- Distrelec Article No.:
- 110-83-815
- Mfr. Part No.:
- FLK-3000 FC
- Brand:
- Fluke
Subtotal (1 unit)*
$970.75
(exc. GST)
$1,116.36
(inc. GST)
FREE delivery for orders over $60.00 ex GST
- Ready to ship from 02 June 2026
Units | Per unit |
|---|---|
| 1 + | $970.75 |
*price indicative
- RS Stock No.:
- 811-1316
- Distrelec Article No.:
- 110-83-815
- Mfr. Part No.:
- FLK-3000 FC
- Brand:
- Fluke
Select all | Attribute | Value |
|---|---|---|
| Brand | Fluke | |
| Product Type | Multimeter | |
| Multimeter Type | Digital | |
| Display Type | Digital | |
| Model Number | 3000 FC | |
| Resistance Resolution | 100mΩ | |
| Functions Measured | AC Current, AC Voltage, DC Current, DC Voltage, Resistance, Temperature | |
| Maximum AC Current Measurement | 400mA ac | |
| Maximum DC Current Measurement | 400mA dc | |
| Maximum DC Voltage Measurement | 1kV dc | |
| Maximum AC Voltage Measurement | 1kV ac | |
| Maximum Resistance Measurement | 50mΩ | |
| True RMS | Yes | |
| DC Current Accuracy | ±0.5 % | |
| AC Current Accuracy | ±1.5 % | |
| DC Voltage Accuracy | ±0.09 % | |
| AC Voltage Accuracy | ± 1 % + 3 | |
| AC Current Resolution | 0.01mA ac | |
| AC Voltage Resolution | 0.1mV ac | |
| DC Voltage Resolution | 0.1 mV dc | |
| DC Current Resolution | 0.01mA dc | |
| Maximum Frequency | 99.99kHz | |
| Resistance Measurement Accuracy | ±0.5 % rdg | |
| Minimum Operating Temperature | -10°C | |
| Battery Life | 250h | |
| Maximum Operating Temperature | 50°C | |
| Weight | 340g | |
| Width | 93mm | |
| Length | 207mm | |
| Height | 47.5mm | |
| Standards/Approvals | No | |
| Series | 3000 FC | |
| Safety Category Level | CAT III, CAT IV | |
| Battery Type | AA Alkaline | |
| Safety Category Voltage | 1000V | |
| Select all | ||
|---|---|---|
Brand Fluke | ||
Product Type Multimeter | ||
Multimeter Type Digital | ||
Display Type Digital | ||
Model Number 3000 FC | ||
Resistance Resolution 100mΩ | ||
Functions Measured AC Current, AC Voltage, DC Current, DC Voltage, Resistance, Temperature | ||
Maximum AC Current Measurement 400mA ac | ||
Maximum DC Current Measurement 400mA dc | ||
Maximum DC Voltage Measurement 1kV dc | ||
Maximum AC Voltage Measurement 1kV ac | ||
Maximum Resistance Measurement 50mΩ | ||
True RMS Yes | ||
DC Current Accuracy ±0.5 % | ||
AC Current Accuracy ±1.5 % | ||
DC Voltage Accuracy ±0.09 % | ||
AC Voltage Accuracy ± 1 % + 3 | ||
AC Current Resolution 0.01mA ac | ||
AC Voltage Resolution 0.1mV ac | ||
DC Voltage Resolution 0.1 mV dc | ||
DC Current Resolution 0.01mA dc | ||
Maximum Frequency 99.99kHz | ||
Resistance Measurement Accuracy ±0.5 % rdg | ||
Minimum Operating Temperature -10°C | ||
Battery Life 250h | ||
Maximum Operating Temperature 50°C | ||
Weight 340g | ||
Width 93mm | ||
Length 207mm | ||
Height 47.5mm | ||
Standards/Approvals No | ||
Series 3000 FC | ||
Safety Category Level CAT III, CAT IV | ||
Battery Type AA Alkaline | ||
Safety Category Voltage 1000V | ||
RoHS Status: Exempt
- COO (Country of Origin):
- US
Fluke Multimeter, 1000V Maximum DC Voltage, True RMS Functionality - FLK-3000 FC
Features & Benefits
• True RMS measurement for accurate non‑sinusoidal waveforms
• 400 mA maximum current range for precision current checks
• Frequency measurement to 99.99 kHz for signal verification
• Resistance down to 50 mΩ for low‑ohm integrity testing
• AA battery operation with 250 h minimum battery life for prolonged field use
**Applications**
• Ideal for preventative maintenance log collection and trend analysis
• Used for motor drive frequency and signal validation in automation systems
• Can be used for HVAC temperature checks via K‑type probes
• Used with remote clamp modules for non‑intrusive current monitoring
How is logged data retrieved for analysis on a PC?
What wireless range can be expected through typical site obstacles?
How does the instrument handle non‑sine AC voltages for accuracy?
What logging capacity and granularity are available for extended monitoring?
Which environmental conditions affect measurement performance?
Note
Supplied with
Related links
- Fluke V3000 FC 3000 FC Handheld Digital Multimeter True RMS 1 kV ac
- Fluke V3001 FC 3000 FC Handheld Digital Multimeter 1 kV ac
- RS PRO S2 Handheld Digital Multimeter True RMS 400 mA dc, 1 kV ac
- Fluke Fluke 279 FC Handheld Digital Multimeter True RMS, 2.5 kA ac
- Sefram 7221 Handheld Digital Multimeter True RMS 1 kV ac
- Testo 760-3 760 Handheld Digital Multimeter True RMS 10 A dc, 1 kV ac
- Keysight Technologies U1241C Handheld Digital Multimeter True RMS 10 A dc, 1 kV ac
- Keysight Technologies U1242C Handheld Digital Multimeter True RMS 10 A dc, 1 kV ac