RCCBs | Residual Current Circuit Breakers | RS
Recently searched

    RCCBs

    An RCCB or residual-current circuit breaker is a safety device used to protect electrical circuits. RCCBs protect people from electric shocks, and electrocution and help prevent electrical fires.

    RS offers an extensive range of high-performance RCCBs and RCDs from leading brands including ABB, Schneider Electric, and Siemens.

    How does an RCCB work?

    An RCCBs incoming current must equal the outgoing current in any circuit. RCCBs can compare the difference in current values between the live and neutral wires. When appliances are working correctly all current entering the appliance through the live wire leaves the appliance via the neutral wire. If a fault occurs some current can flow through the earth wire if there is no earth this can even flow through you. This results in the unequal current flow coming into the device to what is going out, this difference is referred to as residual current.

    What is the difference between an RCCB and an RCD?

    An RCD (residual current device) can keep an electrical system safe by preventing fatal electrical shocks. RCDs can also provide protection from electrical fires. An RCCB is essentially an RCD minus the overload protection. They are typically used in applications where the risk of electric shock is limited. For more detailed information see our in-depth RCDs Guide.

    What are the different types of RCCB and RCD?

    RCCBs and RCDs are usually mounted on DIN rail. They can be 2, 3, or 4 poles. Varying in current ratings, trip sensitivity, and tripping characteristics. All these specifications should be carefully considered depending on your individual needs and application.

    226 Products showing for RCCBs

    Schneider Electric
    RCD
    63A
    3
    Acti9
    30mA
    -
    Vigi iC60
    -
    -
    -
    -
    -
    Schneider Electric
    RCCB
    63A
    4
    Acti9
    -
    -
    A9R
    415V
    -
    -
    -
    -
    Hager
    RCD
    40A
    4
    -
    30mA
    -
    -
    -
    -
    -
    -
    -
    Hager
    RCD
    25A
    2
    -
    30mA
    -
    -
    -
    -
    -
    -
    -
    Schneider Electric
    RCCB
    63A
    4
    Vigi
    300mA
    Type A
    NG125
    230 → 415V ac
    -
    -
    -
    -
    Clipsal Electrical
    RCCB
    63A
    2
    MAX9
    30mA
    Type A
    MX9RC
    240V ac
    -
    -
    -
    -
    Hager
    RCD
    25A
    3
    -
    30mA
    -
    -
    -
    -
    -
    -
    -
    Hager
    RCD
    25A
    4
    -
    30mA
    -
    -
    -
    -
    -
    -
    -
    Hager
    RCD
    25A
    3
    -
    300mA
    -
    -
    -
    -
    -
    -
    -
    ABB
    RCD
    25A
    4
    -
    30mA
    Type AC
    DDA200
    -
    -
    -
    -
    -
    Schneider Electric
    RCCB
    63A
    2
    Resi9
    30mA
    Type A
    R9PR
    230V
    CE
    -
    -
    -
    Legrand
    -
    90A
    2
    -
    -
    -
    -
    250V
    -
    -
    -
    -
    Hager
    RCD
    40A
    2
    -
    30mA
    -
    -
    -
    -
    -
    -
    -
    Schneider Electric
    RCCB
    100A
    2
    Acti9
    -
    -
    A9R
    240V
    -
    -
    -
    -
    ABB
    RCD
    25A
    4
    -
    300mA
    Type AC
    DDA200
    -
    -
    -
    -
    -
    ABB
    RCCB
    40A
    2
    -
    30mA
    -
    DDA200
    230/400V
    -
    -
    -
    -
    Schneider Electric
    RCCB
    100A
    2
    Acti9
    -
    -
    A9R
    240V
    -
    -
    -
    -
    Hager
    RCCB
    63A
    4
    -
    30mA
    -
    -
    -
    -
    -
    -
    -
    Schneider Electric
    RCD
    40A
    3
    Acti9
    300mA
    Type A-SI
    Acti9 iTG40
    400V ac
    -
    -
    Yes
    Green Premium
    ABB
    Self Resetting Short Circuit Limiter
    63A
    1
    -
    -
    -
    S801S
    690V
    -
    -
    -
    -
    Results per page